Our Projects
LOCATION:
88 CAVENDISH ROAD COORPAROO
EQUIPMENT:
TOSHIBA SMMS
8 INDOOR FAN COILS
1 TWIN DIGITAL 10HP INVERTER CONDENSER
Project 1 - Homedeal Air Conditioning (QLD)
LOCATION: 88 CAVENDISH ROAD COORPAROO
EQUIPMENT: TOSHIBA SMMS
This fully renovated old shopfront Queenslander was perfect for the super modular system. The building has 4 different levels all with different thermal aspects, in addition there is 3 skillion flat roofs 1x double storey section and two small pitched roofs.
Whilst it would have been possible to install a traditional ducted system utilising bulkheads and duct risers the temperature control would have been a nightmare.
The added advantage of a modular system is that only small refrigerant piping is run to the various indoor fan units providing a very flexible installation.
For this project the solution was to install the Toshiba SMMS with 8 indoor fan coils connected to a single 10hp twin digital inverter condenser. This allowed every office independent control with the flexibility to run any single office (which happens frequently after hours) or the whole building during normal operation.
| View Project Schematic | PDF File Size: 459Kb |
| View Dynamic Project Floor Plan | View as a PDF (63Kb) |
| View Toshiba Brochure | PDF File Size: 1.5Mb |
| Visit Toshiba Website | ![]() |
| You may need to download the free Adobe reader here to view these PDF files. |
| INDOOR UNITS | ROOF TYPE | FCU |
| Showroom | Pitched roof | Ducted |
| Sales | Pitched roof | Bulkhead |
| Install | Pitched roof | Ducted |
| Accounts | Skillion roof | Bulkhead |
| State Manager | Skillion roof | Bulkhead |
| Reception | Skillion roof | Wall split |
| Service Co-ordinator | Ground floor no roof | Wall split |
| Service Manager | Ground floor no roof | Wall split |
Showroom - This area has roof space above, however it was decided to install the ducted fan coil below the ceiling for display purpose:-
| Before | After |
![]() |
![]() |
Sales - This office could have been serviced from the install unit, however a bulkhead unit was selected to give individual control.
| Before | After |
![]() |
![]() |
Install - This area also has pitched roof space. A ducted fan coil was selected to enable the kitchen and WC to be air conditioned via ducting from single fan coil unit.
| Before | After |
![]() |
![]() |
Accounts - This office had little options due to the flat skillion roof. So a purpose built bulkhead was created to house the small hideaway fan coils, which also have the advantage of individual operation and temperature control.
| Before | After |
![]() |
![]() |
State Manager - This office had little options due to the flat skillion roof. So a purpose built bulkhead was created to house the small hideaway fan coils, which also have the advantage of individual operation and temperature control.
| Before | After |
![]() |
![]() |
Reception - This area has a flat skillion roof. A wall mounted split system was selected which again provides individual operation and temperature control.
| After |
![]() |
Service Co-ordinator - This area has no roof due to the 2nd storey. A wall mounted split system was selected which again provides individual operation and temperature control.
| After |
![]() |
Service Manager - This area has no roof due to the 2nd storey. A wall mounted split system was selected which again provides individual operation and temperature control.
| After |
![]() |